TDS WhatsApp

Product category

Hydroxypropyl Methyl Cellulose (HPMC) for Construction

Hydroxypropyl methyl cellulose (HPMC) is a non-ionic cellulose ether, CAS 9004-65-3, that keeps water in a fresh mortar and controls its rheology. Construction grades are commonly banded from 300 to 250,000 mPa·s, measured on a 2% aqueous solution at 20 °C. HPMC is soluble in cold water and insoluble in hot water.

Spec snapshot

Nine fields a procurement team screens on before reading anything else.

HPMC — typical product identity data. Rows marked material class or industry typical are not a product specification; the value for a specific grade is released with its TDS.
Field Value Basis
Chemical name Hydroxypropyl methyl cellulose (HPMC); INN and pharmacopoeial name: hypromellose Chemistry
CAS number 9004-65-3 CAS registry
HS code 3912.39 — cellulose ethers, in primary forms Customs heading; final classification confirmed per destination customs
Ionic character Non-ionic Chemistry
Appearance White to off-white, free-flowing powder Material class
Solubility Disperses and swells in cold water; insoluble in hot water Material class
Viscosity banding 300 – 250,000 mPa·s, 2% aqueous solution at 20 °C Industry common banding — see the note below
Moisture content Typically ≤ 5–6%, grade-dependent Industry typical window; the value for a specific grade is stated on its TDS
pH, 1% solution Typically 5–8 Industry typical window; the value for a specific grade is stated on its TDS

Two of the rows above describe the material class, not a product specification. Viscosity is quoted at a stated concentration and temperature because the number is meaningless without them, and moisture and pH narrow down by grade. Grade-specific values are only valid when read from the TDS of that grade.

Mechanism

What HPMC does in a mortar

Four functions, each described by mechanism first and site effect second — no adjectives.

  • It holds water against suction

    Dry substrates, warm aggregate and cement all pull water out of a fresh mix. HPMC adsorbs on the binder and aggregate surfaces and raises the viscosity of the pore solution, so less water migrates into the substrate before the binder has set.

    Construction mortars are commonly formulated to land in the 88–95% water-retention window; below roughly 85% the mix stiffens early and adhesion drops, and the exact target depends on how absorbent the substrate is.

    88–95% water retention — filter paper / EN 1015-8

  • It sets the yield stress, which is what stops sagging

    Viscosity band, not dosage alone, governs how the mix behaves on a vertical face: a low band flows and self-levels, a high band holds a bead of adhesive on a wall without slumping.

    Anti-sag is a measured property, not an impression — EN 1308 is the reference method for tile adhesives.

    T classification in EN 12004: slip ≤ 0.5 mm

  • It extends open time

    The same adsorbed layer slows evaporative and suction-driven water loss at the surface, which keeps the adhesive able to wet a tile after trowelling.

    Open time is highly sensitive to ambient temperature, wind and substrate suction, so a formulation that passes at 20 °C can fail on a hot site.

    EN 1346: ≥ 20 min, ≥ 30 min for E-classified products

  • It carries the film that holds the mix together

    In a hardened mortar the cellulose ether remains as a thin continuous film around binder particles and at the aggregate interface, and that film contributes cohesion.

    The same film improves how a redispersible polymer powder distributes through the mix — which is why the two are almost always used together rather than as alternatives.

    Paired with RDP, not substituted for it

One side effect worth designing around: HPMC stabilises air bubbles, and the effect grows with dosage and viscosity. Above roughly 0.6% of binder in a cement system, entrained air can cut compressive strength by a visible margin, and a powder defoamer is usually added rather than accepting the loss.

Selection

How to choose a viscosity grade

Viscosity is not a quality ranking: a higher number does not mean a better product. It is a design parameter that has to match substrate suction, coat thickness, application method and the other additives in the formula.

Industry viscosity bands used for grade selection — not a statement of what this site publishes. Published grades are listed in the grade table below.
BandViscosity, 2% at 20 °C (mPa·s)Where it usually fitsWhat it buys youWhat it costs you
Low300 – 20,000 mPa·sSelf-levelling compounds, gypsum plaster, water-based paint, texture coatingsFlow, high solids, easy air releaseLittle anti-sag; needs another thickener on vertical work
Medium20,000 – 60,000 mPa·sTile adhesive C1/C2, wall putty, masonry and rendering mortarBalanced retention and workability; the usual defaultRequires tuning against local sand
High60,000 – 250,000 mPa·sAnti-sag adhesives, thick putty, high-suction substrates, machine-applied plasterMaximum retention and yield stressHarder mixing, more air entrainment, slower wet-out

Higher viscosity is not automatically better: it raises water demand and can make the mix short. Stay inside the band for your application.

How the number is obtained, and why that matters when comparing suppliers

HPMC viscosity is a relative measurement, not an absolute physical constant. Two data sheets quoting “20,000 mPa·s” can differ by a factor of two if the spindle, rotational speed, concentration or temperature differ. The industry convention is a 2% aqueous solution at 20 °C on a Brookfield viscometer, and even then the spindle and speed must be declared — LV with a small spindle at low speed reads higher than a larger spindle at higher speed on the same sample. Pharmacopoeial monographs take a different route and use a capillary method, so those figures are not interchangeable with Brookfield figures either.

When a supplier quotes a viscosity, ask three things: the concentration, the temperature, and the instrument with spindle and speed. If any of the three is missing, the number cannot be compared with anything.

Grade selection

Choosing the band before the grade

Viscosity is the selection axis. The three bands above cover what HPMC does in a mortar; the band that suits your system is set by the application and by your sand and binder, not by the highest number you can buy. Tell us the application and we will quote the band and the grade code together.

Applications

Which viscosity band fits which application

Dosages below are typical industry ranges for cement- and gypsum-based systems. They are starting points for a trial, not fixed recommendations: local sand grading, cement type, water demand and climate all move the optimum, and re-tuning is normal when a producer changes raw material source.

ApplicationWhy HPMC fitsTypical dosage, % of binderViscosity bandReference method
Tile AdhesiveHPMC holds the mixing water against the suction of the tile and the substrate, so the adhesive stays workable long enough to wet a tile after trowelling; it also raises the yield stress that keeps a ribbed bed from slumping on a vertical face.0.25 – 0.45MediumEN 12004; EN 1346; EN 1348
Wall PuttyIt keeps the paste open and trowellable while the filler and the wall draw water away, and the yield stress it builds stops a thick coat from sagging as it cures.0.30 – 0.60Medium – high—
Gypsum PlasterIt retains water in a mix that would otherwise stiffen as the substrate draws suction, and keeps the paste lubricated so it spreads without lumping; setting time is left to a dedicated retarder, not to the ether.0.05 – 0.30Low – mediumEN 13279; ASTM C472
Waterproof MortarIt keeps the mix workable at the low water-to-binder ratio these systems need, so the mortar wets out and closes pores instead of tearing under the trowel, and the film it leaves holds adhesion on damp substrates.0.20 – 0.40Medium – highEN 14891 (system)
Self-levelingIt sets the yield stress so the compound both flows and self-levels while still resisting segregation and bleeding — the balance a floor compound depends on.0.02 – 0.10LowEN 13813
Masonry MortarIt holds water against the suction of brick and block and keeps the mortar workable in the tub, so the bond develops evenly instead of the mix stiffening before it is placed.0.02 – 0.10Low – mediumEN 1015-8
Water-based PaintIt thickens the aqueous phase, suspends pigment and sets the rheology profile of the paint, which is what governs levelling, spatter and freeze-thaw stability in the can.0.2 – 0.6Low—
EIFS / ETICSIt retains water in the adhesive and base coat while the insulation board and substrate pull it away, and it keeps the paste open long enough to embed the reinforcing mesh without re-wetting.Available on requestAvailable on request—

Dosage is a starting point, not a specification — confirm it on a trial with your own sand, cement and mixing water. Grade-specific values are released with the TDS.

Two rows deserve a warning. In self-levelling compounds the working window is narrow enough that a 0.02% error changes flow visibly, so pre-blend a master batch rather than dosing at the mixer. In gypsum systems, HPMC controls water retention but does nothing for setting time — that needs a dedicated retarder, and adding more HPMC to slow the set is a common and expensive mistake.

Comparison

HPMC against the alternatives

Read across for the property that limits your formula, and read the last column first: it is where each additive stops being the right choice.

AdditiveIonicWater retentionEnzyme resistanceTypical roleWhere it falls short
HPMC (this product)Non-ionicHighGoodBroad-purpose retention and rheology in cement and gypsumEntrains air at high dosage; gels when heated
MHECNon-ionicVery high per unit doseGoodTile adhesive and gypsum systems in some marketsHigher cost per kg; different shear response, so a straight swap needs a trial
HECNon-ionicMedium – highGoodPaints and coatingsPoor delayed solubility; less common in dry-mix mortar
CMCAnionicMediumGoodDetergents, drilling fluids, some putty formulasReacts with calcium in cement systems, so retention falls and the mix can thicken unpredictably
Starch etherNon-ionicLow on its ownLowerWorkability, sag resistance, surface finishAlways blended with a cellulose ether; can reduce strength at high dosage
Redispersible polymer powderNot a cellulose etherNone—Adhesion, flexibility, tensile strength after curingDoes not retain water; complementary to HPMC, not a substitute

Relative comparison for orientation only; the ranking changes with dosage and with the local sand and cement.

Where HPMC is the wrong choice

  • It does not replace redispersible polymer powder

    HPMC gives water retention and rheology; it does not deliver tensile adhesion after heat ageing or the flexibility that EN 12004 C2 tests are looking for.

  • It is not a retarder

    Setting time is controlled by a dedicated retarder, and over-dosing HPMC to slow the set trades a rheology problem for a strength problem.

  • It does not waterproof

    Lowering water absorption needs a hydrophobic additive or a water-repellent powder; HPMC only changes how water moves while the mix is fresh.

  • Above roughly 0.6% of binder in a cement system

    the air it entrains starts to cost compressive strength faster than the extra retention is worth.

Supply

Packaging, storage and compliance

  • Packaging

    25 kg multi-layer paper bag with a polyethylene liner; 500 kg and 1000 kg jumbo bags. Custom-printed packaging is available on request.

  • Storage

    Keep sealed and dry, below about 30 °C, away from direct sunlight and away from odours. The powder is hygroscopic: moisture taken up in storage forms lumps that do not redisperse properly, and a bag that has been open for weeks behaves differently from a fresh one. Under these conditions the usual shelf life is 12 months in the unopened original packaging.

  • Compliance and documents

    Cellulose ethers are generally not classified as dangerous goods for transport, but the classification that applies is the one in the SDS for the specific grade — check it rather than assuming. A TDS, an SDS and a batch COA accompany every shipment, and a Certificate of Origin is issued with the export documents; the COA is the one that matters when a batch has to be released against a specification. The dust is a nuisance rather than a hazard in normal use, so local exhaust ventilation and a dust mask are the standard controls where bags are opened and emptied.

FAQ

Frequently asked questions

What does HPMC do in tile adhesive?

It retains mixing water, extends open time and provides anti-sag. The usual starting point is 0.25–0.45% of binder for C1 and C2 adhesives, rising towards 0.50% where the T classification in EN 12004 applies and slip has to stay at or below 0.5 mm. Dosage is then re-tuned against the actual sand, cement and site temperature.

Which HPMC viscosity should I use for wall putty?

The medium to high band, roughly 40,000–100,000 mPa·s at 2% and 20 °C, is the common starting point, and high-suction substrates or thick coats push towards the upper end. Higher is not automatically better: an over-thick putty traps air, dries unevenly and sands poorly, which is why the band is chosen with the filler and water demand.

How much HPMC is used per tonne of mortar?

For tile adhesive, 0.25–0.45% of binder works out at 2.5–4.5 kg per tonne of binder. For gypsum plaster the usual window is 0.5–3 kg per tonne. Both figures are industry starting points; the correct value comes from a trial with the actual sand, cement and mixing water, because retention depends on what the substrate and the aggregate take out of the mix.

Why does HPMC form lumps when mixed with water?

Standard HPMC swells the moment it meets water, so the outer layer of each particle gels and seals the dry core inside. Use a delayed-solubility grade, dry-blend the powder with the other solids before adding water, and add water under shear. Lumps formed this way do not dissolve later; they show up in the finished surface as hard specks.

What is the difference between HPMC and MHEC?

Both are non-ionic cellulose ethers used for water retention in construction. MHEC generally delivers more water retention per unit dose in cement systems and has the higher gelation temperature, while HPMC has the wider supply base. The real choice is made on trial performance and landed cost for a specific formula, not on the data sheet alone.

Is HPMC the same as hypromellose?

Yes. Hypromellose is the international nonproprietary name and the pharmacopoeial name for hydroxypropyl methyl cellulose; HPMC is the abbreviation used in construction. CAS 9004-65-3 covers the material class. Grades differ in substitution, viscosity and purity, so a pharmaceutical grade is not a drop-in substitute for a construction grade even though the chemical name matches.

Applications

Where this product is used

Tile Adhesive

Water retention and anti-sag for C1 / C2 / C2TE classified adhesives.

Coming soon

Wall Putty

Smooth trowelling, crack resistance and open time for skim coats.

Coming soon

Gypsum Plaster

Controls setting time and water demand in machine-applied plasters.

Coming soon

Waterproof Mortar

Dense film formation and adhesion on wet substrates.

Coming soon

Get the TDS and a sample

Send the application, the binder system and the viscosity band you are working with, and you get back the matching TDS plus a 200 g sample for a plant trial. Technical questions are answered by the application team, not by a sales script. Reply within 12 working hours.

Talk on WhatsApp